Регистрация
deal.by
097368 | CMS-R-BZB-03V - фото 1 - id-p93676980
Характеристики и описание

Техническая спецификация в PDF  

Mechanical values and environment

DesignB
Material
Cable materialPVC
Housing materialFiber glass reinforced PPS
Weight
Net 0,16 kg
Ambient temperature -20 ... 60 °C
Degree of protectionIP67
Installation positionAny, pay attention to marking During mounting it is to be ensured the marking arrows on actuator and read head are opposite each other.
Tightening torque 0,4 ... 0,5 Nm
Number of NO contacts2 NO contacts with internal fuse 100 mA each
ConnectionHard-wired encapsulated cable with cable end sleeves 0.34mm2
Cable length 3 m
Mechanical life 100 x 106
Method of operationMagnetic, reed contact

Electrical connection ratings

Rated conditional short-circuit current 100 A  Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..
Fusing
Power supply / safety contacts, external contact protectionFuse 10 A gG Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..
Switching voltage24 ... 35 V
Switching currentmax.100 mA
Switching characteristicsParallel
Switching voltage according to UL
According to UL Class 2AC/DCmax.24 V
Switching frequency, electrical
At I_min = 10 mAmax.5 Hz  Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..
At nominal current 8 Amax.0,1 Hz  Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..
Switching delay from state change 26 ms  Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..

Miscellaneous

in compliance withEN ISO 13849-1: 2015{} EN 62061: 2005 + AC: 2010 + A1: 2013 + Или отправьте нам запрос на13{} IEC 60947-5-3: 2013

Reliability values acc. to EN ISO 13849-1

Monitoring of the safety guard position
B10D 20 x 106

in combination withEvaluation unit ESM-BA201, ESM-BA202, ESM-BA203, ESM-BA301, ESM-BA302, ESM-BA303, ESM-BA201P, ESM-BA301PandActuator CMS-M-BH

Center offset
At s=3 mm read distance 2,5 mm  Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.
Assured switch-off distance Sarmax.20 mm  The assured switch-off distance s_ar corresponds to the reset distance.
Assured operating distance Sao
With center offset m=0min.7 mm  Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044

Был online: Давно
OOO "ФилФар Технолоджи"
Рейтинг не сформирован
10 лет на Deal.by

097368 | CMS-R-BZB-03V

Под заказ
Цену уточняйте
Доставка
Оплата и гарантии