Описание оборудования | |
---|---|
Magnetic, Non Contact | |
General specifications | |
Detection type | magnetic sampling |
Pulse count | 1000 |
UL File Number | E223176 "For use in NFPA 79 Applications only" , if UL marking is marked on the product. |
Functional safety related parameters | |
MTTFd | 942 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
LED red/green | Operating display / Alignment aid |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC |
No-load supply current | max. 55 mA |
Output | |
Output type | push-pull, incremental |
Voltage drop | < 2.5 V |
Load current | max. per channel 30 mA , short-circuit protected |
Output frequency | max. 1 MHz |
Connection | |
Connector | L = 0.3 m fixed cable with Deutsch connector DTM04-6P |
Standard conformity | |
Degree of protection | DINEN60529, IP67 , IP68 , IP69K |
Climatic testing | DINEN60068-2-30 |
Emitted interference | EN61000-6-4:2007/A1:2011 |
Noise immunity | EN61000-6-2:2005 |
Shock resistance | DINEN60068-2-27, 200g, 6ms |
Vibration resistance | DINEN60068-2-6, 40g, 10...2000Hz |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure , if UL marking is marked on the product. adapters providing field wiring on request |
Ambient conditions | |
Operating temperature | -40 ... 100 °C (-40 ... 212 °F) |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications | |
Material | |
Mass | approx. 190 g |
Rotational speed | max. 30000 min -1 |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |